DESCRIPTION
Catalog # Type
Project
Comments Date
Prepared by
www.cooperlighting.com
SPECIFICATION FEATURES
7.25”
12.00”
13.00”
8.18”
4.63”
4.63”
0.5” - 1.0”
Ceiling
Cut-Out
4.50”dia.
A ...Housing
Housing and plaster frame: 18 gauge CRS
with flat black powder coated internal
finish. Adjustable plaster frame can
accommodate up to 1” ceiling thickness.
B ...System Protection:
Thermal protection provided to guard
against overheating and misuse of
insulation over and around fixture.
Vent holes in housing provide cooler
operation.
C ...Electrical
Integral j-box and electronic or magnetic
low voltage transformer . 120V or 277V
input, 12V output. Junction box is
U.L. listed for through branch wiring.
Includes five 1/2 trade size knockouts
(six knockouts when magnetic xfmr. is
specified)
D ...Lamp
12V MR16 71 watts max.
(not included)
Internal rotation ring with locking
adjustment. Provides 360º rotation of
trim and secures original trim position
after relamping. “POSI-GRIP” bi-pin
lamp socket for firm, mechanical lamp
connection.
E ...Mounting
Hanger Bars and Butterfly Brackets
included for residential and commercial
applications respectively.
Ceiling Cut-Out: 4.50” dia.
ACCURUS
HOUSING
ACT950
New Construction
Housing
for Round Trim
FOR 12V MR16 71 watts max.
ORDERING INFORMATION
Housing
ACT950 =
Accurus New Construction
Housing for Round Trim
w/Integral Transformer
Voltage
120
=
120 volts primary
277
=
277 volts primary
New construction housing for 5” Accurus round trim. For 12V MR16 71
watts max.
For new construction applications. Insulation must be kept 3” from all
sides and at least 1” above the housing.
Specifications and Dimensions subject to change without notice.
RSA Lighting • 7945 Orion Ave. • Van Nuys, CA 91406 • 818-349-3030 • FAX 818-349- 3031
Transformer
ELC
=
Electronic
MAG
=
Magnetic
ACT950
rev 122007
__
__
Page view 0
1

Summary of Contents

Page 1 - New Construction

DESCRIPTIONCatalog # TypeProjectComments DatePrepared bywww.cooperlighting.comSPECIFICATION FEATURES7.25”12.00”13.00”8.18”4.63”4.63”0.5” - 1.0”Ceiling

Comments to this Manuals

No comments