Cooper Lighting IMI-446 User Manual

Browse online or download User Manual for Unknown Cooper Lighting IMI-446. Cooper Lighting IMI-446 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
INSTALLATION INSTRUCTIONS
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
Warning:
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN
SERIOUS INJURY OR DEATH
• This fixture is not suitable for Hazardous
or Classified Locations. Disconnect all
electrical power before installation or
servicing.
• Not for use above cooking equipment.
This product must be installed in
accordance with the applicable installation
code by a person familiar with the
construction and operation of the product
and the hazards involved. Consult a
qualified electrician to ensure correct
branch circuit conductor.
VAPOR-TIGHT
CEILING MOUNT
5/01 IMI-446
LUMARK 1121 HIGHWAY 74 SOUTH PEACHTREE CITY, GEORGIA 30269 5/01 IMI-446 ADH010710
FIXTURE
BLACK LINE (HOT)
WHITE
NEUTRAL
GROUND GREEN/GROUND
For Models:
ICVC1 Series
(200 Watt / 120 Volt) 1/2 NPS
ICVC2 Series
(300 Watt / 120 Volt) 3/4 NPS
Instructions:
Disconnect all electrical power from the source as per the
NEC.
Turn off and lock circuit breakers and remove fuses
protecting the circuit.
Complete connections as per the diagram and the NEC
using approved methods and devices. Proper grounding
must include Ground Screw and Ground Wire.
A surface mounted fixture requires the use of caulking
compounds to provide a moisture tight seal. Use RTV
silicone sealant.
Relamp with proper wattage lamp only -- allow fixture to
cool for relamping.
Lamps: (Sizes vary by manufacturer, so caution must
be taken with Max Lamp Sizes stated.)
ICVC1: 200W MAX; A21 MAX; 120V MIN
ICVC2: 300W MAX; PS25 MAX; 120V MIN
Min supply conductor requirements.
ICVC1: 150ºC
ICVC2: 150ºC
Applications:
• Suitable for operation in Ambients not exceeding 40ºC.
• Suitable for Wet Locations.
• Not for use in dwellings.
• ICVC2 Series - Non-combustible surface only.
Required to comply
with most Construction
Requirements
(Supplied)
Ground Screw
Page view 0
1

Summary of Contents

Page 1 - INSTALLATION INSTRUCTIONS

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for me

Comments to this Manuals

No comments